Variable-Temperature XRD Testing for Drug Components Adapted for Bruker X-Ray Diffractometer

X-ray diffraction (XRD), as a powerful material analysis technique, is widely used in pharmaceutical research. Variable-temperature XRD testing for drug components, which involves collecting and analyzing XRD patterns of drug samples at different temperatures, can reveal physical changes and thermal stability of drugs during temperature variations. This is of great significance for drug development, quality control, and optimization of storage conditions.

 

Variable-temperature XRD testing is an important material characterization technique that observes changes in material crystal structure by altering temperature. The GoGo Instruments XRD Heating/Cooling Stage is an accessory installed on X-ray diffractometers for studying variable-temperature X-ray diffraction of samples. It can precisely control test temperatures and record XRD patterns in real-time. The GoGo Instruments XRD Heating/Cooling Stage is suitable for X-ray structural studies of powder and sheet samples under variable temperatures and is compatible with various major brands of X-ray diffractometers (Bruker, Thermo Fisher, Rigaku, etc.).

 

According to customer requirements, GoGo Instruments customized an XRD Heating/Cooling Stage adapted for Bruker X-ray diffractometers to perform variable-temperature XRD testing on drug components. This product utilizes liquid nitrogen cooling and resistance heating, providing precise temperature control from -190℃ to 600℃ , with optional atmosphere/vacuum chamber. The stage height is adjustable to accommodate samples of different thicknesses. By replacing the top cover, it can also function as an optical heating/cooling stage, enabling multiple uses with a single device.

1659949828143710.png

↑ GoGo Instruments XRD Heating/Cooling Stage, convertible to multiple uses by replacing the top cover ↑


Technical Parameters:

Temperature Control Range: -190℃ ~ 600℃
Temperature Stability: ±0.1℃
Temperature Resolution: 0.1℃
Diffraction Angle (2θ): 0° ~ 164°


布鲁克x射线衍射仪 (1).jpg




布鲁克x射线衍射仪 (2).JPG

↑ On-site adaptation for variable-temperature testing with Bruker D8 series X-ray diffractometer ↑


GoGo Instruments Technology (Shanghai) Co., Ltd. specializes in temperature control technology, offering a range of patented products including probe heating/cooling stages, optical heating/cooling stages, in situ stretching stages, in situ XRD/SEM heating/cooling stages, ultra-high-temperature heating stages, and high/low-temperature test chambers, as well as testing systems for dielectric thermal spectra, electrocaloric effects, charge-discharge testing, and variable-temperature D33 measurements.

Related Products

Safeguarding Research!

【Scan the WeChat QR Code】
【Scan for WeChat Support】

Tel: 18014878671 (Same as WeChat)

Web: www.gogoyq.com

E-mail: wjw@gogoyq.com

Address: No. 308, Baichuanghui, Binhe Road, Suzhou, China

©2021 Gogo Instruments Technology (Shanghai) Co., Ltd.   All right reserved.